Primarily for use with lead acid batteries, easy 4-terminal measurement, 2.7 mm dia. Thermoelectromotive force refers to the potential difference that occurs at junctions between different metals (see figure). }. {{::vm.session.shipTo.lastName}} {{::vm.session.shipTo.firstName}}, {{product.properties.accessoriesDescription}}, / {{product.unitOfMeasureDescription || product.unitOfMeasureDisplay}}, MFG #: {{::relatedProduct.manufacturerItem}}, My Part #: {{::relatedProduct.customerName}}, {{relatedProduct.unitOfMeasureDescription || relatedProduct.unitOfMeasureDisplay}}. resolution, 300 mA max. The RM3548 includes an offset voltage correction function that applies the measurement current in both the positive and negative directions and then uses the resulting detected voltages to eliminate the effects of thermoelectromotive force. The RM3548 is a high-precision, portable resistance meter capable of measuring resistance levels from microohms to megaohms, and is intended primarily for use in testing and maintenance of large equipment, for example, measuring the winding and weld resistances in large motors. Calibration involves comparing the read values of a measuring instrument or data recorder with the corresponding values of a reference tool that meets the reference standards. 230ms. The Hioki RM3548 is a high-precision, portable resistance meter capable of measuring resistance levels from microohms to megaohms, and is intended primarily for use in testing and maintenance of large equipment, for example, measuring the winding and weld resistances in large motors. 230ms. Jau gavome jūsų prašymą ir netrukus jus informuosime. Pateikdami savo el. Copyright © 2020 TestEquity LLC, All rights reserved. 300-32-133). This certificate is proof of your instrument’s reliability for your customers. This website or its third-party tools use cookies, which are necessary to its functioning and required to achieve the purposes illustrated in the cookie policy. If the detected deviation is too large in relation to factory specification, adjustment of your data logger or measuring instrument will be required. .skin-layout-wide .main-content-right {

2 Four-Terminal (Voltage-Drop) Method, Page 129: Appx. : +6221 29368940, High-precision Portable Resistance Meter Measures, Data Acquisition | Oscilloscopes | Memory Recorders, Ground Testers | Voltage Detectors | Phase Detectors, Super Megohmmeters | Electrometers | Picoammeters, Temperature Data Loggers | Compact Loggers, 3 mΩ (3.5000 mΩ display Max., 0.1 µΩ resolution) to 3 MΩ range (3.5000 MΩ display Max., 100 Ω resolution), 10 steps, [at 3 mΩ range] 1 A DC to [at 3 MΩ range] 500 nA DC, -10.0 to 99.9°C, accuracy: ±0.50°C (Temperature Sensor Z2002 and RM3548 combined accuracy), Without OVC: approx. testing current • Measure from 0.0 µΩ (testing current 1 A) to 3.5 MΩ • Easily record up to 1,000 data points in memory simply by applying the instrument’s probes • Smoothly capture temperature-rise test data using interval measurement • Portable design is ideal for maintenance and testing of large equipment, This resistance tester features a portable design that’s easy to use when performing maintenance work in the field. laišką. Probes suited to manual measurement on production lines RM3544/RM3544-01 RM3548 RM3543 RM3542 3541 DSM-8104 1μΩ 3.5MΩ 0.1μΩ 0.1μΩ 0.1μΩ 0.01μΩ 3.5MΩ 1.2kΩ 120MΩ 120MΩ A Full Line-up of HIOKI Resistance Meters to Suit Your Measurement Range 1kΩ 1016Ω Applications Motors, solenoids, choke coils, transformers, wire harnesses Usually the time for the calibration of your device can be handled within 5 working days. Process: After calibration is performed, you will receive an ISO 9001 certificate from Intertek, which is valid for 12 months. Length “A” for all other leads cannot be extended. 4 Temperature Correction Function (Tc), Page 133: Appx. width: 25%; of the calibrated instrument. pašto adreso nenaudosime jokiu kitu tikslu.Privatumo politika. The magnitude of this thermoelectromotive force varies with the temperature of the measurement environment, increasing as the temperature difference grows. Dėkojame. 6 Effect of Thermoelectromotive Force, Appx. Specifically, the phenomenon occurs where measurement probes and measurement targets come into contact, and at connections between measuring instruments and measurement leads.